WebNewer lines, which are black, may not require the same grounding. Unfortunately, even if most of the line does not include CSST, the line needs to be bonded using bare or insulated grounding wire. According to the National Fuel Gas Code (NFGC) Section 7.12.2, CSST lines “shall be electrically continuous and bonded to the electrical service ... WebThe WARDFlex® corrugated stainless steel tubing (CSST) system revolutionized the gas plumbing industry with a time- and cost-saving solution to the inherent problems of rigid steel pipe in delivery installations. With unrivaled flexibility, WARDFlex® eliminates multiple service points at turns and connections and ensures reliable flow from ...
Csst bonding wire
Did you know?
WebFigure 1 Bonding Clamp on Gastite CSST fitting. (Erico clamp # CWP1J, CWP2J or CWP3J) Figure 2 Bonding Clamp on Steel Pipe Segment or Gastite Stub-Out. (Remove … Webd) The bonding conductor [wire] is to be solid or stranded 6 AWG copper [minimum] or equivalent an not to exceed 75 feet in length. The effectiveness of the bond will be improved utilizing the shortest practical conductor [wire] length. e) The bonding conductor [wire] is to be directly and permanently connected to the electrical service ...
WebThe WARDFlex® corrugated stainless steel tubing (CSST) system revolutionized the gas plumbing industry with a time- and cost-saving solution to the inherent problems of rigid … WebOct 22, 2012 · CSST installation and bonding is covered by the National Fuel Gas Code, which requires it to be listed to meet the performance, installation, and construction …
WebApr 19, 2015 · Bonding/grounding clamps shall be installed in accordance with its listing per UL 467 and shall makemetal-to-metal contact with a rigid pipe component or CSST … WebOct 22, 2012 · According to Torbin, the corrugated tubing industry would prefer electrical contractors take over the job of bonding. “Bonding is considered electrical work,” he says. The industry isn’t alone in that desire. Through its CSST bonding awareness campaign, NASFM alerts property owners to enlist a licensed electrical contractor to make the ...
WebOct 26, 2012 · CSST gas piping systems shall be bonded to the electrical service grounding electrode system. The bonding jumper shall connect to a metallic pipe or fitting between the point of delivery and the first downstream CSST fitting. The bonding jumper shall not be smaller than # 6 AWG copper wire or equivalent.
Webrequirement to directly bond the CSST system to the electrical system grounding system. The bonding attachment must be near the service entrance to the building and the connection must be made with a 6 AWG copper wire. This method of bonding will provide additional protection to the CSST system when it is energized by an indirect lightning strike. list of data types in sqlWebJul 5, 2013 · Corrugated stainless steel tubing (CSST) gas piping systems shall be bonded to the electrical service grounding electrode system at the point where the gas service enters the building. The bonding jumper shall be not smaller than 6 AWG copper wire or equivalent.” The purpose of the bonding jumper required by these image that crashes discordWebBonding Clamp on Steel Pipe Fig. 2. Bonding Clamp on First CSST Fitting BONDING WIRE BONDING CLAMP BLACK PIPE COMPONENT OR CSST STUB-OUT BONDING WIRE BONDING CLAMP FIRST CSST FTG. Manufactures of black jacketed CSST products which have been tested and listed to ICC-ES LC 1024, “CSST Utilizing a … image that makes discord crashWebWhen Direct Bonding is Required by Local Code or Manufacturer's Requirement: a) Yellow jacketed Pro-Flex® CSST must be bonded in accordance with this section. b) The … list of data types sqlWebThe gas system only needs to be bonded at one point. Bonding the black iron at the meter to a legal bonding point (anywhere on the grounding electrode system, basically, using a listed tap connector such as an ILSCO GTT-2-2 to connect the gas bond wire to the GEC, or simply by landing the gas bond wire on the intersystem bonding termination device if … list of data types in javaWebApr 3, 2024 · Teh bonding jumper shall be not smaller than 6AWG copper wire or equivalent. Gas piping systems that contain one or more segments of CSST There needs to be a separate bonding wire connected either to the rigid gas piping before the CSST, or directly to one of the CSST nuts. image that represent literatureWebFeb 4, 2009 · Direct Bonding of CSST piping - Manufacturers have provided evidence from a testing center, Lightning Technologies Inc. of Pittsfield, Massachusetts, that additional bonding of CSST products via a bonding jumper helps mitigate damages from indirect lightning strikes. b. One other manufacturer, OmegaFlex, has also provided evidence … list of date formats